120/240Vac/48Vdc/5KW Hybrid Charging Inverter with 145 Max Voc Parallel with up to 6 units
$47.46
$60.75
Description1. Full-digital double closed loop control, combined with advanced SPWM technology to output pure sine wave.2. Two output modes: mains electricity bypass and inverter output or uninterrupted power supply.3. Four charging modes: PV Only, Mains Electricity Priority, PV Priority and PV & Mains Electricity hybrid charging.4. Advanced MPPT technology with 99.9% efficiency.5. User-defined charging parameters setting (voltage, current and mode), and suitable for various types of energy storage batteries.6. Rocker switch for AC output control.7. Power saving mode, reduce no-load loss.8. Intelligent variable-speed fan to efficiently dissipate heat and extend system lifespan.9. Lithium battery activation function, allows lead-acid battery and lithium battery use.10. All-around protection for solar panels includes overload and short circuit protection, under-voltage and over-voltage protection and reverse polarity protection.11. Support variety of user-friendly communication modules, such as RS485 (GPRS, WiFi, Bluetooth), CAN and USB etc., and feasible to connect with computer and mobile phone to realize remote control.12. Expandable for up to 6 units in parallel operation.ModelsHFP4850S80AC modeRated input voltage120VacInput voltage range90Vac-280Vac ±2%Frequency50Hz/ 60Hz (auto-sensing)Parallel connectionFrequency RangeAvailable for 6 units parallel connection47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz);Overload/short circuit protectionBreakerEfficiency>95%Conversion time (bypass and inverter)10ms (Typical value)AC reverse protectionyesMaximum bypass overload current40AInverting modeOutput voltage waveformPure sine waveRated output power(VA)5000Rated output power(W)5000Power factor1Rated output voltage (Vac)120VacOutput voltage error±5%Output frequency range (Hz)50Hz ± 0.3Hz/60Hz ± 0.3HzEfficiency>90% Overload protection(102%<load<125%) ±10%:=”” reporting=”” error=”” and=”” turn=”” off=”” the=”” output=”” after=”” 5=”” minutes<=”” span=””> (125%<load<150%) ±10%:=”” reporting=”” error=”” and=”” turn=”” off=”” the=”” output=”” after=”” 10=”” seconds<=”” span=””>; Load>150% ±10%: reporting error and turn off the output after 5 seconds;</load<150%)></load<125%)>Peak power10000VALoaded motor capacity4HPOutput short-circuit protectionBreakerSpecification of bypass breaker40ARated battery input voltage48V (minimum start voltage 44V)Battery voltage range40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff voltage/overvoltage alarm/overvoltage restoration…settable LCD screen)Power saving modeAC chargeLoad ≤25WBattery typeLead acid or lithium batteryMaximum charge current60ACharge current error± 5AdcCharge voltage range40 –58VdcShort-circuit protectionCircuit breaker and blown fuseBreaker specification40AOvercharge protectionAlarm and turn off charging after 1 minuteSolar chargeMaximum PV opencircuit voltage (VOC)145VdcPV operation voltage range60-145VdcMPPT voltage range60-115VdcBattery voltage range40-60VdcMaximum output power4200WCharge current range of solar energy (settable)0-80ACharge short-circuit protectionBlown fuseWiring protectionAuthentication specificationReverse polarity protectionSpecification authenticationCE(IEC/EN62109-1,-2)、ROHS2.0EMC authentication gradeEN61000Operation temperature range-15°C to 55°CStorage temperature range-25°C ~ 60°CHumidity range5% to 95% (Conformal coating protection)Noise≤60dBThermal dissipationForced air cooling, variable speed of fanCommunication interfaceUSB/RS485(Bluetooth/WiFi/GPRS)/Dry node controlDimension (L*W*D)430mm*338mm*126mmWeight (kg)10
Charging Inverters